Search results for "Voltage regulation"
showing 10 items of 15 documents
Ancillary Services in the Energy Blockchain for Microgrids
2019
The energy blockchain is a distributed Internet protocol for energy transactions between nodes of a power system. Recent applications of the energy blockchain in microgrids only consider the energy transactions between peers without considering the technical issues that can arise, especially when the system is islanded. One contribution of the paper is, thus, to depict a comprehensive framework of the technical and economic management of microgrids in the blockchain era, considering, for the first time, the provision of ancillary services and, in particular, of the voltage regulation service. When more PV nodes are operating in the grid, large reactive power flows may appear in the branches…
Applications of the Fault Decoupling Device to Improve the Operation of LV Distribution Networks
2008
The aim of this paper is to present the operating principle of a new resonant device, called the fault decoupling device (FDD), able to improve power quality in electrical distribution systems. In low-voltage networks, this device can be employed in order to mitigate voltage dips due to faults or large induction motor startup. Moreover, in the presence of distributed-generation (DG) units, the FDD allows one to obtain various benefits such as a reduction of the fault current in each node of the network and an increase in the voltage at the DG unit node. In order to show the performances of the FDD, analytical studies and computer simulations were carried out which took into account various …
Wind Turbine Generation System With Optimized DC-Link Design and Control
2013
This paper presents an optimized capacitance design for the dc link of a back-to-back converter for wind turbine power generation. The design method combines switching ripple and dynamic specifications to give the smallest possible dc-link capacitance and the required proportional-integral compensator for the voltage regulation. Furthermore, a novel concept to globally manage the on/off switching of back-to-back power subconverters, based on a finite-state machine, is presented. The proposed management system keeps control of the dc-link voltage for proper operation of both subconverters regardless of wind or grid conditions.
Reassessment of voltage stability for distribution networks in presence of DG
2016
There is a growing interest in integrating renewable energy based distributed generation (DG) in the electrical power distribution networks. The installation of DG units at distribution level impacts critically the planning and operation characteristics of the network. The type, location, number and capacity of the integrated DGs affects system behavior and performance. In this paper the effect of installing new DGs on the distribution network voltage stability is studied. The optimal location of the newly installed DGs are decided based on the Power Stability Index (PSI) and Voltage Stability Index (VSI). Moreover, Voltage Stability Margin (VSM) of the interconnected DG distribution networ…
A new backward/forward method for solving radial distribution networks with PV nodes
2008
Abstract In this paper, a new backward/forward (b/f) methodology for the analysis of distribution systems with constant power loads is presented. In the proposed method, at each iteration, the loads are considered as constant impedances; in the backward sweep all the network variables (bus voltages and branch currents) are evaluated considering a scaling factor which is determined at the end of the backward phase. Indeed the forward sweep is eliminated and the node voltages calculation does not demand the sequentiality needed in the b/f methodology. The developed method, although deriving conceptually from the b/f methodology, presents only the backward phase in which all the network variab…
Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid
2015
This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…
A back to back method for the temperature rise test of prefabricated substations: A case study
2015
In this work a back to back method is presented which allows to develop heating tests of prefabricated secondary substations with a limited number of supplying equipment (an induction regulator and a capacitor bank). The proposed method makes use of the transformer tap changers to create a voltage difference on the medium voltage side. In this way, only an adjunctive low voltage supply is needed. With the proposed test system, the heating tests are developed on a 1000 kVA prefabricated substation. Thanks to the experimental tests, the class of enclosure of the substation and the operating temperature and resistance of the power transformers are determined, according to the recommendations o…
A New Solution for Low-Voltage Distributed Generation Interface Protection System
2015
In this paper, a new solution is proposed for the remote monitoring and control of distributed generators (DGs) and energy storage systems (ESSs) connected to low-voltage distribution networks. The proposed system fulfills the in-force standard requirements for the connection of DGs to the utility grid. Moreover, it allows implementing some enhanced functions for the remote control of inverters of DGs and ESSs, not only in terms of disconnection but also in terms of voltage regulation and power shuttering. The proposed solution is based on a new interface protection system and a dedicated secondary substation concentrator, which allows the communication between the distributed system operat…
Small-Signal Modeling of a Controlled Transformer Parallel Regulator as a Multiple Output Converter High Efficient Post-Regulator
2004
This paper presents a post-regulator based on the use of a controlled transformer, which adds or subtracts an additional voltage to the output filter of a converter in order to regulate its output voltage. So, their actuation is complementary to that of more known post-regulators, such as the magnetic amplifier (magamp) and synchronous switch post-regulator (SSPR), because the regulation is achieved by controlling the voltage across the filter inductor instead of its charge time. Besides, the post-regulator processes the power in parallel to the one flowing from input to output and only handles a percentage of it. The post-regulation by controlled transformer is suitable of being employed i…
A fuzzy-logic based evolutionary multiobjective approach for automated distribution networks management
2004
In this paper, a methodology to treat constrained scheduling problems based on the repeated application of a fuzzy-logic-based multiobjective algorithm is presented. The application domain is that of automated distribution systems management. In particular, the problem of voltage regulation and power loses minimization is here considered. The classical formulation of the problem of optimal control of shunt capacitor banks and under load tap changers, ULTC, located at high voltage/medium voltage (HV/MV) substations has been coupled with the optimal control of tie-switches and capacitor banks on the feeders of a large radially operated meshed distribution system with the aim of attaining mini…